🚚 Free Worldwide Shipping on All Orders!Shop Now
Hager VME11314SPD 13+14 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) Replacement of VML11214SPD)
HomeStore

Hager VME11314SPD 13+14 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) Replacement of VML11214SPD)

Hager VME11314SPD 13+14 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) Replacement of VML11214SPD)

$90.17

Original: $257.64

-65%
Hager VME11314SPD 13+14 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) Replacement of VML11214SPD)

$257.64

$90.17

The Story

13+14 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device (SPD)

Product Details

  • Rated & Operational Voltage (Un/Ue): 230V a.c 50 Hz
  • Rated Insulation Voltage (Ui): 320V a.c. 50Hz
  • Rated Frequency (fn): 50 Hz
  • Rated impulse withstand voltage (Uimp): 4kV
  • Rated Current of the Assembly (Ina): 100A
  • Rated Current of Assembly Circuit (Inc): Main Switch 100A (marked rated current on device)
  • Types of System Earthing for which the assembly is designed: TNC-S, TT and TN-S when installed in an electrical system conforming to BS 7671
  • Intended locations: Indoor use only
  • Degree of protection: IP2XC with door open / closed and full compliment of devices / blanks fitted.
    Note: Where cables are installed through the top wall of the enclosure, gaps of IP4X to be maintained.
  • Intended use: Intended for use in domestic (residential) or similar premises
  • External design: Wall mounted, surface type, enclosed assembly.
  • Mechanical impact protection: IK05
  • Type of construction: Fixed parts
  • Incoming Line/Neutral terminal: 50mm2
  • Incoming Earth Terminal: 16mm2

Description

13+14 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device (SPD)

Product Details

  • Rated & Operational Voltage (Un/Ue): 230V a.c 50 Hz
  • Rated Insulation Voltage (Ui): 320V a.c. 50Hz
  • Rated Frequency (fn): 50 Hz
  • Rated impulse withstand voltage (Uimp): 4kV
  • Rated Current of the Assembly (Ina): 100A
  • Rated Current of Assembly Circuit (Inc): Main Switch 100A (marked rated current on device)
  • Types of System Earthing for which the assembly is designed: TNC-S, TT and TN-S when installed in an electrical system conforming to BS 7671
  • Intended locations: Indoor use only
  • Degree of protection: IP2XC with door open / closed and full compliment of devices / blanks fitted.
    Note: Where cables are installed through the top wall of the enclosure, gaps of IP4X to be maintained.
  • Intended use: Intended for use in domestic (residential) or similar premises
  • External design: Wall mounted, surface type, enclosed assembly.
  • Mechanical impact protection: IK05
  • Type of construction: Fixed parts
  • Incoming Line/Neutral terminal: 50mm2
  • Incoming Earth Terminal: 16mm2