XFP 1 Loop 16 Zone Addressable Fire Panel (XP95/Discovery protocol)Addressable Fire Systems Apollo XP95/Discovery XFP 1-2 Loop Fire Panels
PRODUCT FEATURES:Â
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apolloâs XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
Technical Specifications:
| Protocol/compatibility |
Apollo XP95/Discovery. |
|---|---|
| Mains supply |
230V 50/60Hz. |
| Mains rated current |
350mA maximum. |
| Internal power supply |
27Vdc nominal. |
| Total output current limited to |
1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA). |
| Quiescent current |
50mA (loop unloaded). |
| Max battery size and type |
2 x 12V 3.2Ah VRLA connected in series. |
| No. of loop drivers |
1. |
| Max. loop output current |
500mA (25V min; 34V max). |
| Max. loop length |
1KM. |
| Max. addressable devices per loop |
126. |
| No. of conventional sounder circuits |
2 (Max. length per circuit is 500m). |
| EOL resistor value |
6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
| Max. sounder output current |
400mA. |
| Auxiliary relays |
3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
| Other outputs |
24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
| Auxiliary inputs |
2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
| PC connection |
PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available. |
| Indicators |
2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst |
| Connections |
Fixed, largest acceptable conductor size 1mm2. |
| Expansion connections |
2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or |
| Product dimensions (mm) |
380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
| Construction & finish |
Plastic lid and base; RAL7035 textured |
| IP Rating |
IP30. |
Description
XFP 1 Loop 16 Zone Addressable Fire Panel (XP95/Discovery protocol)Addressable Fire Systems Apollo XP95/Discovery XFP 1-2 Loop Fire Panels
PRODUCT FEATURES:Â
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apolloâs XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
Technical Specifications:
| Protocol/compatibility |
Apollo XP95/Discovery. |
|---|---|
| Mains supply |
230V 50/60Hz. |
| Mains rated current |
350mA maximum. |
| Internal power supply |
27Vdc nominal. |
| Total output current limited to |
1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA). |
| Quiescent current |
50mA (loop unloaded). |
| Max battery size and type |
2 x 12V 3.2Ah VRLA connected in series. |
| No. of loop drivers |
1. |
| Max. loop output current |
500mA (25V min; 34V max). |
| Max. loop length |
1KM. |
| Max. addressable devices per loop |
126. |
| No. of conventional sounder circuits |
2 (Max. length per circuit is 500m). |
| EOL resistor value |
6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
| Max. sounder output current |
400mA. |
| Auxiliary relays |
3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
| Other outputs |
24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
| Auxiliary inputs |
2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
| PC connection |
PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available. |
| Indicators |
2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst |
| Connections |
Fixed, largest acceptable conductor size 1mm2. |
| Expansion connections |
2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or |
| Product dimensions (mm) |
380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
| Construction & finish |
Plastic lid and base; RAL7035 textured |
| IP Rating |
IP30. |