C-Tec XFP501E-X XFP 1 Loop 16 Zone Addressable Fire Panel (XP95-Discovery protocol)
HomeStore

C-Tec XFP501E-X XFP 1 Loop 16 Zone Addressable Fire Panel (XP95-Discovery protocol)

C-Tec XFP501E-X XFP 1 Loop 16 Zone Addressable Fire Panel (XP95-Discovery protocol)

$498.90
C-Tec XFP501E-X XFP 1 Loop 16 Zone Addressable Fire Panel (XP95-Discovery protocol)—
$498.90

The Story

XFP 1 Loop 16 Zone Addressable Fire Panel (XP95/Discovery protocol)Addressable Fire Systems Apollo XP95/Discovery XFP 1-2 Loop Fire Panels

PRODUCT FEATURES: 

  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Technical Specifications:

Protocol/compatibility

Apollo XP95/Discovery.

Mains supply

230V 50/60Hz.

Mains rated current

350mA maximum.

Internal power supply

27Vdc nominal.

Total output current limited to

1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).

Quiescent current

50mA (loop unloaded).

Max battery size and type

2 x 12V 3.2Ah VRLA connected in series.

No. of loop drivers

1.

Max. loop output current

500mA (25V min; 34V max).

Max. loop length

1KM.

Max. addressable devices per loop

126.

No. of conventional sounder circuits

2 (Max. length per circuit is 500m).

EOL resistor value

6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

Max. sounder output current

400mA.

Auxiliary relays

3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.

Other outputs

24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.

Auxiliary inputs

2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).

PC connection

PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.

Indicators

2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst

Connections

Fixed, largest acceptable conductor size 1mm2.

Expansion connections

2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or

Product dimensions (mm)

380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required).

Construction & finish

Plastic lid and base; RAL7035 textured

IP Rating

IP30.

Description

XFP 1 Loop 16 Zone Addressable Fire Panel (XP95/Discovery protocol)Addressable Fire Systems Apollo XP95/Discovery XFP 1-2 Loop Fire Panels

PRODUCT FEATURES: 

  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

Technical Specifications:

Protocol/compatibility

Apollo XP95/Discovery.

Mains supply

230V 50/60Hz.

Mains rated current

350mA maximum.

Internal power supply

27Vdc nominal.

Total output current limited to

1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).

Quiescent current

50mA (loop unloaded).

Max battery size and type

2 x 12V 3.2Ah VRLA connected in series.

No. of loop drivers

1.

Max. loop output current

500mA (25V min; 34V max).

Max. loop length

1KM.

Max. addressable devices per loop

126.

No. of conventional sounder circuits

2 (Max. length per circuit is 500m).

EOL resistor value

6800Ω 5% Tol. 0/25W (blue, grey, red, gold).

Max. sounder output current

400mA.

Auxiliary relays

3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.

Other outputs

24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.

Auxiliary inputs

2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).

PC connection

PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.

Indicators

2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst

Connections

Fixed, largest acceptable conductor size 1mm2.

Expansion connections

2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or

Product dimensions (mm)

380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required).

Construction & finish

Plastic lid and base; RAL7035 textured

IP Rating

IP30.